Stove lnstalla tion Assembly
Your Whitfield Quest Plus May Be Installed As:
A
freestanding unit with a pedestal placed on a noncombustible floor pad.
A mobile home heater placed on a non-combustible floor pad, with a source of outside air, bolted
down and electrically grounded to the chassis of the home.
Floor Protection
Your Whitfield pellet stove must be
installed on a non-combustible protec-
tive floor pad of minimum
318" thick-
ness material or a masonry hearth. The
hearth or floor pad must extend a min-
imum of
6"
in front of and from each
side of the stove or to the nearest per-
mitted combustible material if less
than
6".
Floor/Hearth Pad
Clearances to
Combustibles
The following minimum clear-
ances to combustible materials
must be maintained. Keep all
combustibles at least 18" (hori-
zontally) away from the glass
windows.
(ALCOVE CLEARANCES)
Maximum Alcove depth: 24".
Minimum Alcove height:
47-112"
Minimum Alcove Width: 37"
-
-
-.
---
Combustible Wall
=